How to judge the electrical properties of lithium-ion batteries?

Electrical performance:

 

(1) Rated capacity: 0.5 C discharge, not less than 2 H for individual cells, and not less than 1 h54 min (95 %) for batteries;

 

(2) 1C discharge capacity: 1C discharge, not less than 57 min (95 %) for individual cells, and not less than 54 min (90 %) for batteries;

 

(3) Low temperature discharge capacity: -20? Discharge of 0.5 C under C, not less than 1 h12 min (60 %) for either monomer or battery;

 

(4) High temperature discharge capacity: 55? Discharge of 0.5 C under C, not less than 1 h54 min (95 %) for individual cells, and not less than 1 h48 min (90 %) for batteries;

 

(5) Charging maintenance and recovery capacity: 28 days at full temperature, discharge time is not less than 1 h36 min (80 %), discharge time is not less than 1 h48 min(90 %);

 

(6) Storage performance: A single cell or battery undergoing storage test should be selected from a capacity of 50 to 60 tins before storage at an ambient temperature of 40 °C? C, relative humidity 45 <UNK> -75 <UNK> environment storage for 90 days. After the expiration of storage, take out the battery and set aside 1h with 0.2 C full charge, discharge with 0.5 C constant current to the termination voltage. The above test can be repeated 3 times and the discharge time is not less than 1h12 min (60 %);

 

(7) Cycle life: The cell or battery is charged with 0.2 C, the 0.5 C discharge is cycled, the test is stopped when the two consecutive discharge capacities are less than 72 min (60 %), the cycle life of the individual cell is not less than 600 times, and the battery cycle life is not less than 500 times;

 

(8) High temperature shelving life: The high temperature shelving life test should be selected from the single battery with a production date of less than three months. Before shelving, a capacity of 50 % ± 5 % should be filled, and then the ambient temperature is 55 °C ± 2? Section C is set aside for 7 days. After 7 days, remove the battery at an ambient temperature of 20 °C ± 5? Set 2 to 5 H under C. The battery is first discharged to the termination voltage at 0.5 C, charged at 0.2 C after 0.5 H, placed at 0.5 H, and then discharged at 0.5 C constant current to the termination voltage, with this capacity as the recovery capacity. The above step is a one-week cycle until the discharge time is less than 72 min (60 %) and the test is over. The shelving life is not less than 56 days (8 weeks cycle).

 

The page contains the contents of the machine translation.

Solar Radiation in Germany in November: Higher Levels Recorded in the South
Huang | Director of R&D

With 20+ years of experience in lithium battery engineering, Huang specializes in battery selection, system design, and certification compliance for industrial and device-level applications.

Request a Custom Lithium Battery Solution
Discuss your application requirements, design options, and validation samples with our engineers.