18650 9.6V 1100mAh High Rate LiFePO4 Battery Pack
Electrical Specifications
| Property | Parameter |
|---|---|
| Product Number | 01DQ0047-06 |
| Cell Model | 18650 LiFePO4 / 1100mAh / 3.2V |
| Battery Configuration | 3S1P |
| Nominal Voltage | 9.6V |
| Nominal Capacity | 1100mAh |
| Rated Energy | 10.56Wh |
| Charging Voltage | 10.95V |
| Discharge Cut-off Voltage | 5V |
| Standard Charging Current | ≤0.5A |
| Standard Discharge Current | 10A |
| Max Continuous discharge current | 10A |
| Internal Resistance | ≤200mΩ |
Mechanical & Environmental
| Property | Parameter |
|---|---|
| Charging Temperature | 0~45℃ |
| Discharge Temperature | -20~55℃ |
| Storage Temperature | 0~45℃ |
| Dimensions | 85.05 × 75.6 × 26.2 mm |
| Weight | 180g |
| Output Type | — |
| Battery Case | Industrial grade |
| Protection System | Short circuit / overcharge / over-discharge / overcurrent protection + SMBUS communication + 12V charging management |
Application Background
This battery solution is designed for telecom base station backup power systems, providing emergency energy support during power outages and ensuring continuous operation of communication infrastructure.
It must deliver high-rate discharge during sudden power loss and maintain stable system operation, requiring strong instantaneous output capability and high reliability.
Project Challenges
Requires 10A continuous discharge and 12A peak discharge capability
Fast switchover response for base station backup power supply
Requires SMBUS communication and real-time monitoring
High reliability under long standby and frequent cycling conditions
Customized Battery Solution
9.6V 3S1P high-rate LiFePO4 configuration for stable medium-voltage output
SMBUS intelligent communication: real-time monitoring of voltage, current, temperature, and SOC
Industrial-grade protection system: overcharge, over-discharge, overcurrent, and short-circuit protection
12V charging management design compatible with standard adapters
Application Results
Ensures stable emergency power supply during grid outages
Supports high-rate discharge for continuous communication operation
Improves system monitoring and operational visibility
Enhances overall reliability and safety of backup power systems
We support flexible customization based on your project requirements, including:
- Voltage range: 3.2V – 72V
- Capacity range: 100mAh – 100Ah
- Electrical performance design: Charge/discharge parameters, C-rate, internal resistance, temperature performance
- Mechanical design: Appearance, dimensions, housing material, and integrated structural engineering
- BMS design: Battery protection, cell balancing, and communication protocols (SMBus / I2C / UART)