11.1V 6.5Ah Low Temperature Battery Pack
This battery is designed for environmental monitoring equipment used in field data collection and low-temperature outdoor monitoring scenarios. It ensures stable operation at -40°C with reliable discharge and communication support, delivering long-lasting power, stable output, and high durability in compact form.
Electrical Specifications
| Attribute | Parameter |
|---|---|
| Product Number | 39DZ090-02 |
| Cell Model | 8067100 / 6500mAh / 3.7V |
| Battery Configuration | 8067100-3S1P |
| Nominal Voltage | 11.1V |
| Nominal Capacity | 6.5Ah |
| Rated Energy | 72.15Wh |
| Charging Voltage | 12.6V |
| Discharge Cut-off Voltage | 7.5V |
| Standard Charging Current | ≤2A |
| Standard Discharge Current | 2A |
| Max Continuous discharge current | 2A |
| Internal Resistance | ≤250mΩ |
Mechanical & Environmental
| Attribute | Parameter |
|---|---|
| Charging Temperature | 0~45℃ |
| Discharge Temperature | -40~55℃ |
| Storage temperature | -20~45℃ |
| Dimensions | 107 × 68 × 24.8 mm |
| Weight | 380g |
| Battery Case | PVC |
| Communication Protocol | SUMbus |
| Protection System | Short circuit / Overcharge / Overdischarge / Overcurrent / Balancing protection |
Application Background
This battery solution is designed for environmental monitoring equipment, widely used in field data acquisition and continuous low-temperature monitoring scenarios.
The system must operate reliably at -40°C while maintaining stable data collection and transmission, requiring strong low-temperature discharge performance, communication stability, and power reliability.
Project Challenges
- Stable discharge required at extreme low temperature (-40°C)
- Continuous operation for long-term environmental monitoring
- Harsh outdoor deployment conditions requiring high safety and reliability
- Limited device space requiring compact and lightweight design
Customized Battery Solution
- Low-temperature polymer cell enabling stable discharge at -40°C
- Integrated SUNbus communication for real-time data and status monitoring
- Multiple protection system: overcharge, overdischarge, overcurrent, short-circuit, and balancing protection
- Compact and lightweight structure for portable monitoring devices
Application Results
- Reliable operation under extreme -40°C environments
- Improved stability of long-term field data acquisition
- Real-time battery status visibility via communication system
- Extended cycle life, improving overall equipment service lifespan
We support flexible customization based on your project requirements, including:
- Voltage range: 3.2V – 72V
- Capacity range: 100mAh – 100Ah
- Electrical performance design: Charge/discharge parameters, C-rate, internal resistance, temperature performance
- Mechanical design: Appearance, dimensions, housing material, and integrated structural engineering
- BMS design: Battery protection, cell balancing, and communication protocols (SMBus / I2C / UART)