48V 52Ah LiFePO4 Battery Pack
This is a 48V LiFePO4 battery for medical cart systems, used in mobile hospital equipment and clinical ward applications. It supports continuous multi-device operation with RS485 smart communication, delivering stable output, long runtime, and high safety performance in demanding medical environments.
Electrical Specifications
| Attribute | Parameter |
|---|---|
| Product Number | 37DZ012-01 |
| Cell Model | IFP28148115A/3.2V/52Ah |
| Battery Configuration | 15S1P |
| Nominal Voltage | 48V |
| Nominal Capacity | 52Ah |
| Rated Energy | 2496Wh |
| Charging Voltage | 54.75V |
| Discharge Cut-off Voltage | 30V |
| Standard Charging Current | ≤26A |
| Standard Discharge Current | 35A |
| Max Continuous Discharge Current | 60A |
| Internal Resistance | ≤180mΩ |
Mechanical & Environmental
| Attribute | Parameter |
|---|---|
| Charging Temperature | 0~45℃ |
| Discharge Temperature | -20~60℃ |
| Storage Temperature | -20~35℃ |
| Dimensions | 315 × 275 × 145 mm (±1mm) |
| Weight | 20Kg |
| Output Type | Power Output Terminal |
| Battery Case | Sheet Metal Case |
| Communication Protocol | RS485 |
| Protection System | Short Circuit / Overcharge / Over-discharge / Overcurrent / Temperature / Balance Protection |
Application Background
This battery solution is designed for medical cart equipment, suitable for mobile medical power supply, clinical rounds, and healthcare information terminals.
The system requires stable energy support during continuous mobile operation, powering multiple medical loads with high demands on runtime endurance, output stability, communication management, and safety performance.
Project Challenges
Requires 6–12 hours continuous operation for medical cart applications
High instantaneous load current up to 60A during peak operation
Multiple devices running simultaneously, causing significant load fluctuations
Strict safety and stability requirements in hospital mobile environments
Customized Battery Solution
48V 52Ah LiFePO4 high-capacity configuration for long-duration medical cart power supply
RS485 communication with BMS SOC management for real-time monitoring and fault warning
Multi-protection system (overcharge/overdischarge/overcurrent/short circuit/temperature/balancing) ensuring system safety
Sheet metal enclosure for enhanced impact resistance and medical-grade durability
Application Results
Supports 6–12 hours continuous operation per charge for medical carts
System stability improved by approx. 20%+, reducing power failure risk
Real-time SOC monitoring enhances operational and maintenance efficiency
Improved overall equipment reliability for multi-department mobile medical scenarios
We support flexible customization based on your project requirements, including:
- Voltage range: 3.2V – 72V
- Capacity range: 100mAh – 100Ah
- Electrical performance design: Charge/discharge parameters, C-rate, internal resistance, temperature performance
- Mechanical design: Appearance, dimensions, housing material, and integrated structural engineering
- BMS design: Battery protection, cell balancing, and communication protocols (SMBus / I2C / UART)